+86-576-84277977

What is the Injection Molding Cycle? How to Calculate and Optimize It?

Sep 01, 2026

What is the Injection Molding Cycle?

The injection molding cycle (also known as the molding cycle) refers to the total time required for an injection molding machine to complete one full part. It spans from the moment the mold closes until it closes again for the next cycle. As the core metric for measuring injection molding production efficiency, it directly determines equipment capacity, labor productivity, and the manufacturing cost per unit.

Composition and Calculation of the Injection Molding Cycle

A complete injection molding cycle consists of molding operation stages and auxiliary operation stages. The basic calculation formula is:

Molding Cycle = Mold Closing Time + Injection/Filling Time + Holding (Packing) Time + Cooling Time (including plasticizing time) + Mold Opening Time + Ejection Time

 

Detailed breakdown of each stage:

  • Mold Closing Time: The time it takes for the mold to close and lock. This depends on the machine's mold stroke and closing speed.
  • Injection/Filling Time: The time it takes for the molten resin to flow through the sprue and completely fill the cavity. This is influenced by injection speed, injection rate, and melt viscosity.
  • Holding (Packing) Time: After filling, the time during which continuous pressure is applied until the gate freezes, compensating for the shrinkage of the cooling melt.
  • Cooling Time: The time after holding pressure ends, allowing the part, gate, and runner system to cool to a state where it can be safely ejected. Cooling time typically accounts for 50% to 80% of the entire molding cycle, making it the longest phase.
  • Plasticizing Time: The time required to melt and meter the resin for the next shot. In actual calculations, plasticizing usually occurs simultaneously with cooling. The cycle time takes the greater value between the cooling time and the plasticizing time.
  • Mold Opening and Ejection Time: Includes the time for the mold to open, the ejection mechanism to actuate, and the robot or operator to remove the part.

        1fb7dc75ca715911e0f62083c3d34fa                 1740642966538

How to Scientifically Optimize the Injection Molding Cycle?

Optimizing the molding cycle is a systematic project. It cannot be achieved by blindly increasing injection speed or compressing cooling time, as this easily triggers mass defects such as sink marks, flash, and dimensional deviations. Scientific optimization should follow this logic and direction:

1. Focus on the Core Bottleneck: Cooling System Optimization

Since cooling time accounts for the vast majority of the cycle, improving the mold's heat dissipation efficiency is the core breakthrough for speeding up production:

  • Inherent Mold Design: Optimize the layout of cooling channels to shorten the distance between the channels and the cavity. For deep cavities or areas with concentrated heat, use high thermal conductivity inserts like beryllium copper, or employ conformal cooling channels to match the contour of the cavity.
  • On-site Temperature Control Management: Use mold temperature controllers or chillers to maintain a constant water temperature (typically 15-25°C for general plastics, 25-40°C for engineering plastics). Ensure the cooling water is in a turbulent state to improve heat transfer efficiency, and establish a regular descaling and cleaning mechanism to prevent scale buildup from halving the heat dissipation.

 

2. Refined Injection Process Adjustment

Once the cooling system meets the standards, adjust the process strictly in the fixed sequence of "melt temperature → injection speed → injection pressure → holding pressure":

  • Multi-stage Injection: Adopt a "slow-fast-slow" injection profile. Inject slowly at the gate to prevent jetting, use high speed for the main body to reduce viscosity, and slow down at the end to facilitate venting, thereby shortening the overall injection time.
  • Precise V/P (Velocity/Pressure) Switchover: The optimal switchover point should be set when the cavity is 95% to 98% filled. This avoids short shots caused by early switchover and prevents flash and excessive internal stress caused by late switchover, typically saving 2 to 5 seconds of holding time.
  • Scientific Holding Pressure Setting: Holding time is not the longer, the better; its endpoint should be "gate freeze-off." You can use the "weighing method" to gradually extend the holding time. When the part weight no longer increases, that is the optimal holding time, eliminating ineffective waiting time.

 

3. Eliminate Hidden Time Wastes in Mechanical Movements

  • Mold Opening/Closing and Ejection Optimization: Optimize the mold movement profile (slow-fast-slow) to reduce unnecessary slow-speed phases and empty strokes. Use high speed for the empty travel of the ejection stroke, and only use low speed when actually ejecting the part.
  • Automated Part Removal: Use robots for automatic part removal instead of manual labor to eliminate the waiting time caused by human intervention. This not only saves 2 to 5 seconds per cycle but also ensures absolute cycle stability.

 

4. Upfront Product and Material Optimization

  • Product Design: Maintain uniform wall thickness as much as possible and avoid locally thick sections. Cooling time increases exponentially with the square of the wall thickness. Thick walls should be replaced with ribs or hollow structures.
  • Material Selection: Provided that product performance requirements are met, select modified materials with high fluidity, high-speed crystallization characteristics, or higher heat deflection temperatures. This allows parts to be demolded at higher temperatures, significantly shortening the cooling time.
Send Inquiry